Navigation




Variables
Concept details
Key | Value |
---|---|
method_id | CO_322:0000197 |
method_name | Adjusted GY - Computation |
ontology_id | CO_322 |
ontology_name | MAIZE |
method_class | Computation |
method_description | Calculate shelled grain yield per unit area adjusted to 12.5% grain moisture. |
formula | (EarW_kg __FieldWB/1000)*(100-Moi_pct__STD)/(100-12.5)*(10000/PlotSize_m2)*(Shell_pct/100) |
language | EN |
created_at | 2023-11-22-12:37:09 |